Example system configuration
(machining center cramp)
The unit accumulates pressure in the accumulator and stops the electric motor with the set upper pressure limit of the pressure switch. Using the oil pressure accumulated in the accumulator, the unit maintains the pressure of the circuit and carries out
Hydraulic circuit diagram
Package Specifications
NRP-10-12-10 | NRP-10-24-10 | Remarks | |
---|---|---|---|
Pump capacity | 3.0cm3/rev | 5.0cm3/rev | |
Motor output - No. of poles | 1.2kW-4P | 2.4kW-4P | S3:Repeated operation |
Rate of loaded operating time (per minute) |
15% (9seconds) | 10% (6seconds) | |
Tank specification | Resin tank (10 liters) | ||
Options | |||
Pressure switch | One output point (open collector) | Fixed pressure type | |
Accumulator | 0.7 liters | ||
Reducing valve | Pressure adjustment range: 1.5 - 7.0MPa |
||
Tank specifications | Steel plate tank (10 liters) | Steel-plate tank has a special design number |
Explanation of model number