| Item / Model No. | ESD-G01-**10 20 -12 |
ESD-G03-** 40-(**)-12 80-(**)-12 |
ESD-G04- **140-(**)-12 |
ESD-G06- **250-(**)-13 |
|---|---|---|---|---|
| Maximum operating pressure MPa {kgf/cm2} |
25 {255} | |||
| Rated flow rate L/min | 10/20(*1) | 40/80(*1) | 140(*1) | 250(*1) |
| Maximum flow rate L/min | 25(*2) | 100(*2) | 140(*2) | 250(*2) |
| Pilot pressure MPa {kgf/cm2} |
- | At least 1.0 {10}(*3) | ||
| Pilot flow rate L/min | - | At least 2 (*4) |
At least 3 (*4) |
At least 5 (*4) |
| T port allowable back pressure MPa {kgf/cm2} |
25 {25.5} | Internal Drain: 2.5 {25.5} | ||
| External Drain: 21 {214} | ||||
| Rated current mA | 850 | |||
| Coil resistance |
20(20°C) | |||
| Hysteresis % | 5 max.(*5) | |||
| Response time s | 0.04(*6) | 0.05(*6) | 0.08(*6) | 0.1(*6) |
| Mass kg | 2.2 | 7 | 9.2 | 15 |
Notes : *1.Value when pressure drop volume to P to A and P to B is
P =1.0MPa {10kgf/cm2}.
*2.Indicates maximum throughput volume value between each port.
*3.Indicates differential between the pilot port and tank port, or drain port.
*4.Value when 0.1 second is assumed for the response time from zero to the rated flow volume.
*5.Value when a Nachi-Fujikoshi special amplifier is used.
*6.Response time is typical value for a supply pressure of 14MPa {143kgf/cm2} and fluid temperature of 40°C (kinematic viscosity: 40mm2/s).