| Item | Specifications | ||
|---|---|---|---|
| Type C | Type 1 | Type 3 | |
| Maximum working pressure | 10Mpa | 25MPa | |
| Maximum flow | 50L/min | ||
| Pressure adjustment range | 0.1 to 3.5MPa | 1.0 to 10.0MPa | 2.5 to 25.0MPa |
| Operating temperature | -10 to 75°C | ||
| Ambient temperature | 0 to 50°C | ||
| Protection structure | JIS C0920 IP54 | ||
| Supply voltage | DC12 to 24V +/- 10% | ||
| Output element | Transistor open corrector output (photo coupler insulation) |
||
| Load current | Maximum: DC35 V 100 mA | ||
| Residual voltage | 1.2 V or less | ||
| Hysteresis adjustment range | Approximately 1 to 10 % of set value | ||
| Response speed | 20 msec or less | ||
Example of wiring

Note : When connecting a compact relay, make sure to connect counter voltage absorption element (diode) parallel to load.