Specifications
Power-supply voltage | 3Ø AC200 to 240V, 50/60Hz(200V Class) 3Ø AC380 to 480V, 50/60Hz(400V Class) |
rated input current | 9.7A/1.5kW, 13.4A/2.2kW(200V Class) 5.9A/1.5kW, 8.2A/2.2kW(400V Class) Note) In the 400V grade the input current value for the fan cooler is not included. |
Pressure adjustment range | A2:1.5 to 4.0MPa A3:3.5 to 6.0MPa A4:5.5 to 8.0MPa |
Discharge amount (no-load) | 0A* : 14L/min 1A* : 28L/min |
HYDRAULIC OILs | Standard mineral-based hydraulic fluid (equivalent to ISO VG32) |
OIL TEMPERATURE | Use at temperatures below 60°C. |
color | black (Semi-gloss) |
ambient temperature / humidity | 0 to 35°C/20 to 80%RH (No condensation) (Keep the unit away from water-soluble cutting fluid mist. ) |
Mounting dimensions
Type | Motor (kW-P) |
Measurment | Approximate mass (kg) |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LA | LB | LC | LD | LE | LF | LG | LH | LI | H | L | |||
NSP-10E-15V*A*-21 | 1.5-4 | 510 | 5 | 501 | 265 | 236 | 164 | 119 | 172 | 30 | 10L | 8.5L | 48 |
NSP-10E-22V1A*-21 | 2.2-4 | 540 | 35 | 521 | 256 | 174 | 129 | 55 | |||||
NSP-20E-15V1A*-21 | 1.5-4 | 510 | 5 | 601 | 365 | 236 | 164 | 119 | 252 | 50 | 20L | 16L | 51 |
NSP-20E-22V1A*-21 | 2.2-4 | 540 | 35 | 621 | 256 | 174 | 129 | 58 |
·approximate mass, Does not include the hydraulic fluid
Explanation of model No
Hydraulic circuit diagram
Precautions for use